Pump Efficiency Calculator

Enter flow, head (or suction and discharge pressure) and the power the pump set draws. Get wire-to-water efficiency, pump-only efficiency, hydraulic power and energy per cubic metre.

Quick Answer

Pump efficiency = (ρ × g × Q × H) ÷ input power. With Q in m³/s and H in metres, ρ × g × Q × H ÷ 1000 gives hydraulic power in kW.

  • Divide by electrical input for wire-to-water efficiency; by shaft power for the pump alone.
  • 1 bar of differential pressure ≈ 10.2 m of water head.
  • Take flow, pressure and power readings at the same time, at a steady duty point.

Inputs

Result

Wire-to-water efficiency
54.5%
Pump efficiency (excl. motor)
—%
Hydraulic (water) power
4.09kW
Electrical input power
7.50kW
Total head
30.0m
Energy per m³ pumped
0.150kWh/m³
Assumes clean water at about 20 °C (1,000 kg/m³). Take flow, pressure and power at the same moment.

The pump efficiency formula

Hydraulic power (kW) = ρ × g × Q × H ÷ 1000
  ρ = 1,000 kg/m³ (water) · g = 9.81 m/s²
  Q = flow in m³/s (m³/h ÷ 3600, or LPM ÷ 60,000)
  H = total head in m = (Pdischarge − Psuction) in bar × 10.19

3-phase input power (kW) = √3 × V × I × PF ÷ 1000
Wire-to-water efficiency = Hydraulic power ÷ Input power × 100
Pump efficiency = Hydraulic power ÷ (Input power × Motor efficiency) × 100
Energy per m³ = Input power ÷ (Q in m³/h)

Use the power the pump set actually draws from the supply, measured with an energy meter — not the motor's nameplate kW. A motor rated at 7.5 kW may be drawing far more or far less than that at the pump's real duty point, and the efficiency result moves one-for-one with the power figure.

What you need to measure pump efficiency continuously

  • Electrical input. A Titan energy meter gives kW, voltage, current and power factor per phase, logged continuously.
  • Head. The Titan Pump Controller combines Titan metering with two pressure sensors, one on the suction side and one on the discharge side, so head is measured alongside electrical input.
  • Flow. Needs a separate flow meter. Neither Titan nor the pump controller measures flow, so without one you can track the trend of power and head at a fixed duty, but not a true efficiency figure.

For borewells, tubewells and pumping stations spread across sites, the Titan Pump RMS reports run hours, power availability and electrical faults over 4G.

Frequently asked questions

Pump efficiency, head and performance testing.

Pump efficiency = hydraulic power ÷ power going in. Hydraulic power (kW) = ρ × g × Q × H ÷ 1000, where ρ is water density (1,000 kg/m³), g is 9.81 m/s², Q is flow in m³/s and H is total head in metres. Divide by the electrical input power to get wire-to-water efficiency (pump and motor together), or by the motor's shaft power to get the pump's own efficiency.
It is the efficiency of the whole pump set — motor and pump together — measured from the electricity drawn at the supply to the useful work done on the water. It is the figure that matters for the electricity bill, because it includes motor losses as well as pump losses.
For water, 1 bar is about 10.2 m of head (100,000 Pa ÷ (1,000 kg/m³ × 9.81 m/s²)). Use the difference between discharge and suction pressure. If the pump is lifting water from below, suction pressure is negative, which adds to the head.
Run the pump at a steady duty point and, at the same time, record flow (from a flow meter), suction and discharge pressure, and electrical input power (from an energy meter). Repeat at two or three valve positions if you can. Plot the results against the pump's published curve at the same flow — a pump running well below its curve is a candidate for inspection or replacement.
Not accurately. Head and electrical input can be measured continuously, but efficiency needs flow too. Without a flow meter you can still track the trend of input power and head at a fixed duty, which shows wear over time, but you cannot state an efficiency figure.
It is the energy used to move one cubic metre of water. For pumping stations, water supply and irrigation, it is often easier to track than efficiency because it links directly to the electricity bill. A rising kWh per m³ at the same head means the pump set is getting less efficient.

Monitor pump efficiency, not just run hours