MFM Meter — 3 Phase Multifunction Meter, Class 0.5S
A 3-phase multi function meter for LT panels, switchgear, sub-metering and industrial captive plants — also specified as a multi-function energy meter, digital panel meter or panel-mount meter. Class 0.5S accuracy, RS485-only from ₹ 6,500 + GST or RS485 Modbus + Modbus TCP + MQTT + WiFi at ₹ 11,000 + GST, in a 96 × 96 mm bezel for the standard 92 × 92 mm panel cutout (DIN-rail variant available as Titan).
- Class 0.5S (IEC 62053-22)
- Accuracy
- RS485 Modbus · TCP · MQTT · WiFi
- Comms
- 96 × 96 mm panel / DIN rail
- Form factor
- CE marked
- Certification

- Accuracy
- Class 0.5S
- IEC 62053-22 energy, Class 0.5 V / I
- Voltage
- 48–500 V
- 3-phase 4-wire or 3-wire
- Current input
- 100–2,000 A
- External 5 A CTs, ring or split-core
- Connectivity
- RS485 · Ethernet · WiFi
- Ethernet and WiFi on the full-comms model
- Protocols
- Modbus · BACnet · MQTT
- RTU/TCP, MS/TP and IP
- Mounting
- 96 × 96 mm
- Fits the 92 × 92 mm panel cutout
Trusted by energy & industrial leaders






Customers include Tata Power, BSES, HAL (Hindustan Aeronautics), Hero MotoCorp, Torrent Power and Indian Railways.
What does MFM stand for?
MFM stands for multifunction meter — sometimes written multi function meter or multi-function meter. It is a single panel-mounted instrument that replaces the separate ammeter, voltmeter, power-factor meter, frequency meter and energy meter that an LT panel would otherwise carry, measuring all of those parameters on all three phases at once and reporting them over a communication bus.
In an electrical panel, the MFM is the instrument on the front door that tells you what the feeder behind it is actually drawing. What separates one from another is accuracy class, which parameters it measures, and how it gets that data out — which is what the rest of this page covers.
At a glance
- What it is
- A 3-phase multifunction meter (MFM) — also called a digital panel meter, trivector meter, or network analyser — measuring V, I, kW, kVA, kVAr, PF, kWh / kVAh / kVArh, demand, and harmonics on every phase.
- Best for
- LT panel builders, switchgear OEMs, industrial sub-metering, captive power plants, ESCOs, MEP consultants, and tenant-billing buildings.
- Standards
- Designed to IEC 62053-22 Class 0.5S energy accuracy; CE marked. Specification boilerplate and Modbus register map provided for tender BOQs on request.
- Programmes
- Catalogue MFMs: no MOQ, regular orders from stock, 200+ units 4 weeks from PO. White-label from 1000 units, 4 weeks. Custom enclosure or bespoke Modbus map quoted per project. 2-year standard warranty.
A Cloud-Native MFM for LT Panels and Industrial Sub-Metering
The India panel-meter category — which includes brands like Selec, Elmeasure, Schneider, and L&T — covers the full spectrum of 3-phase multi function meters used on LT panels, switchgear and industrial sub-distribution. Titan is built for the same buyer set: electrical contractors, plant engineers, switchgear OEMs, ESCOs, and MEP consultants.
What Titan adds to the category is a cloud-native data path integrated with the meter itself. Built-in WiFi and Ethernet stream data directly to our cloud Energy Management System or any third-party MQTT broker. RS485 Modbus RTU and Modbus TCP stay live in parallel for switchgear PLC and SCADA integration. One 96 × 96 mm panel unit, three concurrent comms paths on the full-comms model (RS485 Modbus, Modbus TCP, MQTT), and Class 0.5S accuracy.
Built for LT panel builders, captive power plant operators, industrial submetering projects, ESCOs running M&V, and MEP consultants writing tender specs. Buy the same hardware as a standalone meter, a switchgear-integrated panel meter, or a cloud-monitored asset — same device, three deployment modes.
What the Titan MFM Does
Six capabilities that separate a cloud-native Class 0.5S MFM from a legacy Class 1.0 panel meter.
Full Parameter Set on Every Phase
V, I, kW, kVA, kVAr, PF, frequency, kWh, kVAh, kVArh, demand (kW/kVA MD), THD and individual harmonics — per phase. The full parameter set buyers expect from a 3-phase multifunction meter, in one 96 × 96 mm panel-mount unit.
Class 0.5S Revenue-Grade Accuracy
Designed to IEC 62053-22 Class 0.5S — the class C&I sub-billing and check-metering specs typically call for, with accuracy specified down to 1% of rated current — so sub-billing, M&V, and EnPI numbers stay defensible.
RS485 Modbus or BACnet + Ethernet + WiFi + MQTT
The full-comms model ships RS485, Modbus TCP over Ethernet, BACnet/IP, MQTT, and WiFi — so the same hardware can feed a switchgear PLC, an in-house SCADA, a building BMS, an MQTT broker, and a cloud dashboard without any additional gateway. The RS485 port carries Modbus RTU or BACnet MS/TP, selected at commissioning.
96 × 96 mm Panel Mount
96 × 96 mm bezel that drops straight into the standard 92 × 92 mm LT panel cutout — the fascia format panel builders and switchgear OEMs already design around. The same electronics also ship in DIN-rail form as Titan for cabinet and per-feeder installs; same accuracy, two install patterns.
Built-In Cloud Connectivity — No Gateway
The full-comms model connects to our cloud Energy Management System directly over WiFi or Ethernet — no separate energy-server PC and no Modbus gateway in the data path between the meter and the dashboard.
Made in India, Class 0.5S Accuracy
Designed and manufactured in India to IEC 62053-22 Class 0.5S, and CE marked. Specification boilerplate and the Modbus register map are provided to specifiers and panel builders on request.
MFM Specifications
| Parameter | Specification |
|---|---|
| Type | 3-phase 4-wire / 3-phase 3-wire multifunction energy meter (MFM) |
| Accuracy class | Class 0.5S energy (IEC 62053-22), Class 0.5 voltage / current |
| Voltage range | 48 V to 500 V (higher-voltage systems only via a customer-installed PT) |
| Current input | LTCT — external Class 0.5S CTs, 100 A–2,000 A primary, 5 A secondary; ring (solid-core) or split-core |
| Parameters measured | V (L-L, L-N), I, kW, kVA, kVAr, PF, frequency, kWh, kVAh, kVArh (import/export), demand (kW, kVA, A — block + sliding), THD-V, THD-I, individual harmonics up to 31st |
| Demand window | Configurable sliding / fixed-block, 1 / 5 / 15 / 30 / 60 min |
| Communication | RS485-only model: Modbus RTU or BACnet MS/TP (selectable). Full-comms model adds Modbus TCP and BACnet/IP (Ethernet) and MQTT (WiFi / Ethernet) |
| Display | Backlit LCD, configurable scroll, instantaneous + accumulated + demand pages |
| Standards | Designed to IEC 62053-22 (Class 0.5S active) and IEC 62053-24 (Class 1 reactive); EMC per IEC 61000-4 series |
| Certification | CE marked (Titan series) |
| Mounting | 96 × 96 mm bezel, 92 × 92 mm panel cutout; same electronics also available in DIN-rail form as Titan |
| Operating conditions | −25 °C to +70 °C, 5–95% RH non-condensing, EMC designed to the IEC 61000-4 series |
Datasheet (PDF): Titan meter datasheet — the MFM is the same meter in a 96 × 96 mm panel housing
Connectivity — Beyond RS485-Only Panel Meters
Most panel meters stop at RS485 Modbus and rely on a separate gateway to reach a network. Titan keeps the RS485 Modbus RTU that panel builders expect, and the full-comms model adds Modbus TCP over Ethernet, MQTT to any broker, and built-in WiFi — all running at the same time, with no gateway, converter, or energy-server PC in the data path. Serve a local switchgear PLC or SCADA over Modbus while the same meter streams live to the cloud.
Modbus RTU over RS485
The protocol every panel builder expects — Modbus RTU on a standard 2-wire RS485 bus, Master or Slave, with the full register map exposed for switchgear PLCs, SCADA, and legacy BMS.
Modbus TCP over Ethernet
Where most legacy panel meters stop at RS485, the full-comms model adds a built-in Ethernet port running Modbus TCP — poll the meter directly over your LAN at full speed from any Modbus TCP master, with no RS485-to-Ethernet converter or serial gateway in the panel.
MQTT + WiFi to the Cloud
The full-comms model publishes over MQTT to any broker (AWS IoT, Azure IoT Hub, HiveMQ, Mosquitto, or the Tech OVN cloud) over built-in WiFi or Ethernet. A genuinely cloud-native panel meter — not an RS485 meter bolted to a third-party gateway.
Communication & Connectivity
| Parameter | Specification |
|---|---|
| RS485 | 2-wire bus, Master or Slave — Modbus RTU or BACnet MS/TP, selectable; full register map |
| Ethernet | Built-in 10/100 port — Modbus TCP and BACnet/IP, no serial gateway required |
| WiFi | Built-in 2.4 GHz (802.11 b/g/n) |
| Modbus | Modbus RTU (over RS485) + Modbus TCP (over Ethernet) |
| BACnet | BACnet MS/TP (over RS485) + BACnet/IP (over Ethernet or WiFi) — no gateway |
| MQTT | Publish to any broker (AWS IoT, Azure IoT Hub, HiveMQ, Mosquitto, Tech OVN cloud), TLS-secured |
| HTTP / TCP push | JSON instant frame pushed to an endpoint you specify |
| REST API | On-device provisioning and commissioning — WiFi setup, transport config, RS485 role, OTA, status and event reads |
| Simultaneous | Modbus and MQTT run at the same time — serve a local panel/SCADA while streaming to the cloud |
| Cloud | Direct to the Tech OVN Energy Management System over WiFi / Ethernet — no separate energy-server PC |
| Updates | OTA firmware over WiFi — no site visits, no USB |
MFM vs Power Quality Meter vs Energy Meter vs Smart Meter
Indian electrical procurement uses several overlapping names for adjacent products. Here is the side-by-side view so the right device ends up in the right tender BOQ.
| Dimension | MFM (Titan) | Power Quality Meter | Basic Energy Meter | Smart / Utility Meter |
|---|---|---|---|---|
| What it measures | V, I, kW, kVA, kVAr, PF, kWh, kVAh, kVArh, demand, harmonics — per phase | Same as MFM plus full PQ events (sags / swells / transients / flicker) | Active energy (kWh) only, sometimes kVA + PF | MFM parameters + utility-tariff features (TOU, anti-tamper, prepaid) |
| Accuracy class | Class 0.5S (IEC 62053-22) | Class S PQ (IEC 61000-4-30) + 0.5S energy | Class 1.0 or 2.0 typical | Class 1.0 (residential) or 0.5S (industrial) |
| Where it's installed | LT panel, sub-distribution, captive plant, industrial submetering | Critical feeders, OT/ICU, data centre IT load, manufacturing PQ-sensitive equipment | Single-load monitoring, basic kWh tracking | Utility service entrance for billing |
| Typical user | Electrical contractor, plant engineer, switchgear OEM, ESCO, MEP consultant | Power quality auditor, MV/HV engineer, industrial reliability team | Building owner, light commercial submeter | DISCOM, utility company, AMI rollout |
| Indian terminology | MFM, multifunction meter, trivector meter, panel meter, network analyser | PQ meter, power quality analyser, Class A / Class S analyser | kWh meter, energy meter, basic meter | Smart meter, AMI meter, utility meter |
The right TechOVN product for each: Titan (MFM), Titan PQ (power quality meter, coming soon), and our utility smart meter range (DISCOM-side).
Where the MFM Is Used
Six common procurement contexts for a Class 0.5S 3-phase multifunction meter in India.
LT Panel Builders & Switchgear OEMs
Panel-mount or DIN rail MFM as a standard fitment on LT distribution boards, MCCs, PCCs, and LT panels. 96 × 96 mm panel (92 × 92 mm cutout) or DIN rail formats with RS485 Modbus for switchgear PLC integration.
Industrial Submetering
Production lines, compressed-air systems, chiller plants, large motors. Class 0.5S accuracy on every circuit, dashboard view across the plant, alerts on demand or PF deviation.
Captive Power Plants & DG Sets
Track DG output independently from grid import, calculate cost per kWh, detect synchronisation issues, and feed data into ABT-style internal billing models for multi-tenant captive plants.
MEP Consultants & Electrical Contractors
Specify Class 0.5S MFM with RS485 + MQTT + WiFi for tender BOQs — designed to IEC 62053-22. Specification boilerplate available on request for inclusion in tender documents.
Sub-Metering for Tenant Billing
Per-floor, per-tenant, per-unit submetering with chargeback-grade accuracy. Class 0.5S gives tenant bills a defensible accuracy basis when a reading is disputed.
Solar PPA & Behind-the-Meter Verification
Independent measurement on the solar generation side and the grid-import side, alongside the DISCOM net meter (not a replacement for it), with bidirectional kWh + kVArh and time-of-use tariff support.
The Titan Family — One Platform, Multiple Meter Types
The Titan MFM is one variant in a family of Class 0.5S meters from the same in-house design and production line. Pick the variant that matches the circuit, the application, or the tender specification — they all feed the same cloud platform.
How to Buy the MFM
Price, order quantities, lead time and what is quoted separately — stated up front, so you can plan a panel build or a tender against it.
| Parameter | Specification |
|---|---|
| Price — RS485-only model | ₹ 6,500 + GST per meter. RS485 only (Modbus RTU or BACnet MS/TP) — no WiFi, no Ethernet. The variant for panel builds and BMS/SCADA integration where no cloud connectivity is needed. |
| Price — full-comms model (WiFi + Ethernet + RS485) | ₹ 11,000 + GST per meter, CTs extra (₹ 950–2,500 + GST each) — the same price as Titan, which is the same meter in a DIN-rail housing. Runs Modbus RTU, Modbus TCP and MQTT simultaneously with no gateway. |
| Other Titan variants | Titan 4G (DIN rail, 4G + RS485, MQTT only) ₹ 11,500 + GST at /products/titan-4g. Titan Group — four single-phase circuits per meter with a grid / DG split per circuit — on the RS485, WiFi or 4G model, at /products/titan-group. |
| MOQ — catalogue | None. A single panel or a tender sample is a valid order. |
| Lead time | Regular orders ship from stock. Orders of 200 units or more ship 4 weeks from confirmed PO. |
| Warranty | 2 years standard from date of dispatch. |
| Panel cutout | 96 × 96 mm bezel for the standard 92 × 92 mm panel cutout, so it drops into an existing MFM slot without panel rework. A DIN-rail variant is available as Titan. |
| Current transformers | Quoted separately. The meter is LT CT-operated with a 5 A secondary: Tech OVN supplies Class 0.5S ring (solid-core) or split-core CTs from 100 A to 2,000 A primary, or you can source Class 0.5S -/5 A CTs locally. |
| Branded / white-label | White-label — your logo, faceplate and packaging on this SKU — from 1000 units, 4 weeks from PO. Custom enclosure, bespoke Modbus register map or custom firmware is quoted per project under the OEM / ODM programme. |
| Integration effort | The Modbus register map, MQTT command reference and worked decode examples are published openly, so your engineers can build and test the integration before any commitment. |
| Cloud dependency | None required. RS485 Modbus RTU and Modbus TCP are local and need no internet connection; the Tech OVN platform is optional. |
| Manufacturing | Designed, built, calibrated and tested in Delhi NCR, India. |
Frequently Asked Questions
What an MFM is, how it differs from a trivector meter / network analyser / smart meter, Class 0.5S vs Class 1.0, RS485 + MQTT + WiFi comms, and tender compliance.
Technical document
Titan Communication & Integration Guide
Complete Modbus RTU and TCP register map, MQTT topic scheme and command reference, plus push payload formats — for panel and BMS integration without a discovery exercise.
PDF · Modbus register map, MQTT topics and commands, push payloads, provisioning API
Specifying an MFM for a panel, plant or tender BOQ?
Talk to our team. Class 0.5S Titan MFM, RS485-only or with RS485 Modbus + Modbus TCP + MQTT + WiFi, DIN rail or 96 × 96 mm panel mount. Datasheet, Modbus register map, and tender boilerplate on request.