Skip to main content

Titan Group · 4 circuits · Class 0.5S

Titan Group — Four Single-Phase Circuits in One Meter

Titan Group is a group energy meter: one Class 0.5S Titan meter that measures four single-phase circuits, keeps grid and DG energy separately for each circuit, and reports over RS485, WiFi + Ethernet or 4G. It is for monitoring and cost allocation, not prepaid billing, and starts at ₹6,500 + GST per meter — about ₹1,625 per circuit.

From ₹6,500 + GSTper meter, 4 circuits (about ₹1,625 per circuit) · WiFi model ₹11,000 · 4G model ₹11,500 · CTs extra
  • 4 circuits per meter
  • Grid / DG per circuit
  • Class 0.5S
  • Not prepaid

Buying 10 or more? Project pricing within 24 hours.

Tech OVN Titan DIN-rail energy meter, which runs the Titan Group four-circuit mode
Request Quote

Trusted by energy & industrial leaders

Tata Power logo
BSES logo
HAL (Hindustan Aeronautics) logo
Hero MotoCorp logo
Torrent Power logo
Indian Railways logo

Customers include Tata Power, BSES, HAL (Hindustan Aeronautics), Hero MotoCorp, Torrent Power and Indian Railways.

At a glance

What it is
A Titan firmware mode that meters four single-phase circuits in one Class 0.5S meter, with grid and DG energy per circuit.
Best for
Shops, floors, suites, PG rooms and single-phase machines where each needs its own grid and DG total.
Models
RS485 ₹6,500 · WiFi + Ethernet ₹11,000 · 4G ₹11,500 — all + GST per meter, CTs extra.
What it is not
Not a prepaid meter. It has one relay, so it cannot disconnect circuits one at a time.

How Titan Group Works

The Titan metering engine, configured to treat its inputs as four single-phase circuits instead of one three-phase feeder.

Four Circuits, One Meter

Each of the four single-phase circuits gets its own energy registers, its own name in the dashboard and its own share of the bill. One meter to mount, wire and commission instead of four.

Grid / DG Split Per Circuit

When the 12 V DG-on signal is present, each circuit's energy goes into its own DG registers. You see who used how much grid power and how much generator power — the split that decides most cost-allocation disputes.

Class 0.5S on Every Circuit

The same metering engine as Titan, designed to IEC 62053-22 Class 0.5S — not an indicative sub-meter. Per-circuit kWh, kVAh, kvarh, power factor and demand.

Pick How the Data Leaves

Group mode runs on the RS485-only model (into your BMS or PLC), the WiFi + Ethernet model (Modbus TCP, BACnet, MQTT, cloud) and Titan 4G (MQTT over cellular).

Three Models, Same Four Circuits

Choose by where the data has to go. Price per circuit is the meter price divided by four, before CTs.

ModelPrice per meter (+ GST)Per circuitData out
Titan Group RS485₹6,500₹1,625RS485 (Modbus RTU / BACnet MS/TP)
Titan Group₹11,000₹2,750WiFi + Ethernet + RS485, MQTT
Titan Group 4G₹11,500₹2,8754G (MQTT only) + RS485

The 4G model is Titan 4G in group mode; the WiFi model is Titan; the RS485 model is the RS485-only Titan.

Where Group Metering Pays Off

Anywhere several single-phase users share one supply — and one generator.

Shops in a Mall or Market

Four shops per meter, each with grid and DG energy, for monthly cost recovery by the owner or maintenance agency.

Floors & Departments

Allocate energy to floors, wings or cost centres in an office or plant without a meter per feeder.

Co-working & Business Centres

Meter cabins and suites for recharge of electricity and DG backup in the monthly invoice.

PGs, Hostels & Staff Quarters

Room or block-level consumption for fair cost sharing. Monitoring only — the meter does not cut supply per room.

Machines & Single-Phase Loads

Track four single-phase machines, lighting circuits or HVAC units for energy per product or per process.

Generator-Backed Sites

Where DG backup is billed at a different rate from grid power, the per-circuit DG split is the whole point.

Specifications

Group-mode specifics. Full metering specifications are on the Titan page.

Titan Group

ParameterSpecification
Circuits4 single-phase circuits per meter (Titan Group mode)
AccuracyClass 0.5S active energy per circuit (designed to IEC 62053-22)
Per-circuit datakWh, kVAh, kvarh, V, I, kW, PF, demand — grid and DG registers kept separately
Grid / DGPer-circuit DG registers switched by a 12 V DG-on signal; DG run hours
RelayOne relay per meter — not per circuit, so the meter is not a prepaid meter
ModelsRS485-only, WiFi + Ethernet + RS485, or 4G (MQTT only) + RS485
CTsExternal CTs, 5 A secondary — sized per circuit (from ₹950 + GST each)
MountingDIN rail

One Titan Group vs Four Single-Phase Meters

The usual alternative is a row of separate meters — and, for a DG split, often a second row.

Titan GroupFour separate single-phase meters
Meters to mount and wire14
AccuracyClass 0.5SUsually Class 1.0
Grid / DG split per circuitYesRarely — often a second meter per circuit
Data outRS485, WiFi / Ethernet / MQTT, or 4GOften none, or RS485 + a separate data logger
Per-circuit disconnect (prepaid)No — one relayOnly on prepaid meters

Frequently Asked Questions

Group metering, prepaid, DG split, pricing and integration.

Group metering means measuring several consumers or loads from one metering point — for example, four shops, four floors or four machines on one meter, each with its own energy total. Titan Group does this for four single-phase circuits on one Class 0.5S meter, with grid and DG energy kept separately for every circuit.
No. Titan Group has a single relay, so it cannot switch off one circuit while the others stay on — which a prepaid system needs. It is a monitoring and cost-allocation meter: it tells you exactly how much grid and DG energy each circuit used, so you can bill or recover the cost.
Titan Group RS485 is ₹6,500 + GST per meter (about ₹1,625 per circuit), Titan Group with WiFi + Ethernet is ₹11,000 + GST (about ₹2,750 per circuit), and Titan Group 4G is ₹11,500 + GST (about ₹2,875 per circuit). CTs are extra. Buying 50 or more? Ask for project pricing.
Yes. When the generator runs, a 12 V DG-on signal tells the meter, and each circuit's energy accumulates in its own DG registers until grid power returns. The grid and DG totals for each circuit are available on the meter, over its communication port and in the Energy Intelligence Platform.
Yes. The RS485 port speaks Modbus RTU or BACnet MS/TP, so every circuit's registers can be read by a BMS, PLC or billing software. The WiFi + Ethernet model adds Modbus TCP, BACnet/IP and MQTT, and the 4G model publishes over MQTT.
Each circuit is metered to Class 0.5S. Titan Group is a sub-meter behind the utility meter for cost allocation; whether a sub-meter may be used for resale billing depends on your state's electricity regulations and your supply agreement, so check those for your site.

Related

Sub-metering for business

How Tech OVN meters floors, lines and tenants behind the utility meter.

Learn More →

Titan 4G

Titan with a 4G module, MQTT only — group mode included.

Learn More →

Dual-source energy meter

How grid and DG energy are kept in separate registers.

Learn More →

Generator monitoring system

DG performance, condition, fuel and cost.

Learn More →

Get a Titan Group quote

Tell us how many circuits, the load on each, and whether you have DG backup.