Solution
Energy Audit Equipment That Stays Installed
Fast to Deploy. Permanent Option.
Energy audit equipment is the metering and logging hardware an energy auditor installs to record a site's consumption, load profile and power factor during a survey. Tech OVN makes Titan Audit for auditors and ESCOs: Class 0.5S per IEC 62053-22, split-core CTs that clamp onto conductors in minutes, usually with no shutdown, and PDF reports from a phone. We supply the equipment; the audit is yours.
Modern energy audit equipment has to deploy fast, run unattended, and produce defensible reports — without shutting down equipment. Titan Audit clamps onto live conductors with split-core CTs, runs for as long as you need (days, weeks, or permanently), and generates branded PDF audit reports from a phone over WiFi.

The Audit Cost Problem
Traditional portable power loggers cost lakhs of rupees to buy or a significant weekly fee to rent. They require trained technicians to install, collect data for a few weeks, then get removed — leaving the facility blind again. Auditors spend more time managing logger logistics than analysing data.
Titan Audit changes the economics. It deploys as fast as a portable logger but stays as long as you need it — days, months, or permanently. It costs less than a typical portable logger, and a qualified electrician on the facilities team can install it. ESCOs deploy it across multiple sites simultaneously and convert audits into ongoing M&V contracts (via our Energy Management System) without buying new hardware.
Compare Titan Audit to portable loggers →What Titan Audit Solves
Five reasons facility teams and ESCOs choose Titan Audit over traditional portable loggers.
Deploys in Minutes
Split-core CTs clamp around existing conductors, so most feeders don't need a shutdown. Voltage leads connect to the load, or plug the meter into a power socket for current-only logging. Work inside live panels should be done by a qualified electrician following your site's safety procedure.
Defensible Class 0.5S Data
Same metering engine as the Titan base meter. Class 0.5S accuracy, designed to IEC 62053-22, with Class 0.5S split-core CTs from 100 A to 1000 A (5 A secondary).
PDF Reports From the Phone
The Titan App connects over WiFi and generates branded PDF audit reports on-site: consumption summary, load profile, power factor trend, TOU breakdown, on/off runtime log. No laptop.
Audit → Permanent Monitoring
When the audit ends, leave the meter installed. It connects to the Energy Intelligence Platform for continuous M&V, baseline tracking, and post-retrofit verification — same hardware.
No Cloud Subscription Needed for Audits
The phone app generates audit reports locally from the meter's stored data. The cloud platform is optional — only needed if you want continuous monitoring after the audit ends.

Compliance Use Cases
From BEE PAT in India to ASHRAE Level 2/3 and ISO 50001 — Titan Audit supplies the measured data that compliance-driven audit work relies on.
BEE PAT (India)
The Bureau of Energy Efficiency's Perform, Achieve and Trade scheme relies on measured baseline and assessment-year data from designated consumers. Titan Audit's TOU registers, harmonics to the 31st and Class 0.5S accuracy support the measurement side of PAT workflows; the PAT documentation and verification remain with the designated consumer and the accredited energy auditor.
ASHRAE Level 2 & Level 3
ASHRAE Standard 211 Level 2 and Level 3 audits break energy use down by major system (HVAC, lighting, motors, plug loads), and deeper audits often call for measured data. Deploy Titan Audit on each system feeder for the period your audit plan sets, and export load profiles for the report.
ISO 50001 Initial Energy Review
The standard requires identifying significant energy uses (SEUs) and establishing energy performance indicators (EnPIs). Titan Audit captures the load data; the platform calculates and tracks the EnPIs.
Retrofit M&V
Baseline before the retrofit, leave the meter installed, verify savings after. Same hardware, no swap-out, no second deployment cost.
Audit-to-Subscription Path
The Titan Audit value chain typically runs:
- 1
Deploy for the audit period
- 2
Generate the PDF audit report from the phone app
- 3
Leave installed as a permanent monitor on the same circuit
- 4
Subscribe to the Energy Intelligence Platform for ongoing analytics
ESCOs particularly benefit: the audit hardware doubles as the M&V hardware, the customer never has to buy a second device, and the ongoing subscription becomes recurring revenue.

Frequently Asked Questions
Seven common questions about energy audit equipment, BEE PAT, and ASHRAE audits.
Related Solutions & Products
Audit, reduce, monitor — an end-to-end energy optimisation stack.
Energy Efficiency
Cut factory electricity costs through demand management, PF correction, and schedule optimisation.
Learn More →Energy Monitoring System
Circuit-level real-time monitoring across sites — the permanent successor to a temporary audit deployment.
Learn More →Titan Audit Energy Logger
Split-core CT energy logger. Installs in minutes, usually without a shutdown. PDF reports from phone. Class 0.5S.
Learn More →Energy Audit ROI Calculator
Model the economics of an audit on your facility using your own tariff and cost inputs.
Learn More →Portable energy logger
Clamp-on 3-phase power and energy logger for energy auditors and ESCOs — survey a panel without a shutdown, then move it to the next site.
Learn More →Ready to speed up your next audit?
Talk to our team about Titan Audit for ESCO projects, BEE PAT measurement work, or post-retrofit M&V.
