Skip to main content

Solution

Energy Audit Equipment That Stays Installed

Fast to Deploy. Permanent Option.

Energy audit equipment is the metering and logging hardware an energy auditor installs to record a site's consumption, load profile and power factor during a survey. Tech OVN makes Titan Audit for auditors and ESCOs: Class 0.5S per IEC 62053-22, split-core CTs that clamp onto conductors in minutes, usually with no shutdown, and PDF reports from a phone. We supply the equipment; the audit is yours.

Modern energy audit equipment has to deploy fast, run unattended, and produce defensible reports — without shutting down equipment. Titan Audit clamps onto live conductors with split-core CTs, runs for as long as you need (days, weeks, or permanently), and generates branded PDF audit reports from a phone over WiFi.

Energy audit equipment deployed on a DIN rail — Titan Audit by Tech OVN

The Audit Cost Problem

Traditional portable power loggers cost lakhs of rupees to buy or a significant weekly fee to rent. They require trained technicians to install, collect data for a few weeks, then get removed — leaving the facility blind again. Auditors spend more time managing logger logistics than analysing data.

Titan Audit changes the economics. It deploys as fast as a portable logger but stays as long as you need it — days, months, or permanently. It costs less than a typical portable logger, and a qualified electrician on the facilities team can install it. ESCOs deploy it across multiple sites simultaneously and convert audits into ongoing M&V contracts (via our Energy Management System) without buying new hardware.

Compare Titan Audit to portable loggers →

What Titan Audit Solves

Five reasons facility teams and ESCOs choose Titan Audit over traditional portable loggers.

Deploys in Minutes

Split-core CTs clamp around existing conductors, so most feeders don't need a shutdown. Voltage leads connect to the load, or plug the meter into a power socket for current-only logging. Work inside live panels should be done by a qualified electrician following your site's safety procedure.

Defensible Class 0.5S Data

Same metering engine as the Titan base meter. Class 0.5S accuracy, designed to IEC 62053-22, with Class 0.5S split-core CTs from 100 A to 1000 A (5 A secondary).

PDF Reports From the Phone

The Titan App connects over WiFi and generates branded PDF audit reports on-site: consumption summary, load profile, power factor trend, TOU breakdown, on/off runtime log. No laptop.

Audit → Permanent Monitoring

When the audit ends, leave the meter installed. It connects to the Energy Intelligence Platform for continuous M&V, baseline tracking, and post-retrofit verification — same hardware.

No Cloud Subscription Needed for Audits

The phone app generates audit reports locally from the meter's stored data. The cloud platform is optional — only needed if you want continuous monitoring after the audit ends.

Titan App generated PDF audit report — consumption summary, load profile, power factor trend

Compliance Use Cases

From BEE PAT in India to ASHRAE Level 2/3 and ISO 50001 — Titan Audit supplies the measured data that compliance-driven audit work relies on.

BEE PAT (India)

The Bureau of Energy Efficiency's Perform, Achieve and Trade scheme relies on measured baseline and assessment-year data from designated consumers. Titan Audit's TOU registers, harmonics to the 31st and Class 0.5S accuracy support the measurement side of PAT workflows; the PAT documentation and verification remain with the designated consumer and the accredited energy auditor.

ASHRAE Level 2 & Level 3

ASHRAE Standard 211 Level 2 and Level 3 audits break energy use down by major system (HVAC, lighting, motors, plug loads), and deeper audits often call for measured data. Deploy Titan Audit on each system feeder for the period your audit plan sets, and export load profiles for the report.

ISO 50001 Initial Energy Review

The standard requires identifying significant energy uses (SEUs) and establishing energy performance indicators (EnPIs). Titan Audit captures the load data; the platform calculates and tracks the EnPIs.

Retrofit M&V

Baseline before the retrofit, leave the meter installed, verify savings after. Same hardware, no swap-out, no second deployment cost.

Audit-to-Subscription Path

The Titan Audit value chain typically runs:

  1. 1

    Deploy for the audit period

  2. 2

    Generate the PDF audit report from the phone app

  3. 3

    Leave installed as a permanent monitor on the same circuit

  4. 4

    Subscribe to the Energy Intelligence Platform for ongoing analytics

ESCOs particularly benefit: the audit hardware doubles as the M&V hardware, the customer never has to buy a second device, and the ongoing subscription becomes recurring revenue.

Titan App audit workflow — clamp, commission, monitor, report from the phone

Frequently Asked Questions

Seven common questions about energy audit equipment, BEE PAT, and ASHRAE audits.

In minutes. Clamp the split-core CTs around the conductors, connect voltage leads (or plug the meter into a power socket for current-only logging), open the Titan App, and you're logging.
Usually not. Split-core CTs clamp around conductors without disconnecting the load. Because the work is inside live panels, installation should be done by a qualified electrician following your site's safety procedure — if a panel can't be worked on safely while live, schedule a short isolation.
Yes. The Titan App generates PDF reports locally on the phone from the meter's stored data — no cloud connection or subscription needed for audit mode.
Same Class 0.5S metering engine. Titan uses permanent CTs for fixed installation. Titan Audit uses split-core clamp-on CTs for zero-downtime deployment — temporary or permanent.
It supports PAT workflows. A meter can't be 'PAT compliant' by itself — PAT compliance belongs to the designated consumer. Titan Audit provides the Class 0.5S measurements (energy, demand, PF, harmonics to the 31st, TOU registers) that baseline and assessment-year measurement work draws on.
Yes. Priced for permanent installation (₹15,100–82,500), Titan Audit can be left on the circuit for continuous monitoring. Connect it to the Energy Intelligence Platform for ongoing M&V and condition monitoring.
It can supply the measured data. Deploy one Titan Audit per system feeder (HVAC, lighting, motors, plug loads) for the logging period your audit plan sets, and export the load profiles for the report. The audit itself — and its conformance to ASHRAE Standard 211 — is the auditor's work.

Ready to speed up your next audit?

Talk to our team about Titan Audit for ESCO projects, BEE PAT measurement work, or post-retrofit M&V.