Solution
EV Charging for Hospitals & Healthcare
Staff. Visitors. Ambulances. One Stack.
Hospital charging station installation that meets the reliability and electrical-safety bar of a healthcare facility. 22 kW AC and DC fast chargers, segregated from critical-load circuits, with priority routing for ambulance EV readiness. Designed and manufactured in Haryana.
Why hospitals are deploying EV charging
Four drivers that go beyond sustainability PR.
Staff Retention Benefit
Medical staff increasingly drive EVs. Offering on-site charging (especially for night-shift staff) is a tangible retention perk at minimal cost per hire.
Visitor Amenity
Hospital visits often mean 2–6 hour dwell times — a natural fit for AC charging. Chargers near the main entrance become a wayfinding and goodwill amenity.
Ambulance EV Readiness
As ambulance fleets transition to EV (several state governments are piloting this), hospitals need guaranteed-charge infrastructure that doesn't compete with non-critical loads.
Electrical Safety & Resilience
Hospitals have strict safety requirements. EV circuits must be isolated from critical-load circuits, surge-protected, and designed to not interfere with medical equipment.
Charging zones for healthcare facilities
Each zone has distinct use cases, power needs, and access rules.
Main Entrance / Visitor Parking
2–6 × 22 kW Type 2 chargers. OCPP billing or validation via hospital app. Prominent signage and wayfinding.
Staff Parking
4–12 × 7.4 kW or 11 kW Type 2 chargers with RFID access (staff-only). Optional payroll-integrated billing (₹/kWh deducted from salary).
Emergency / Ambulance Bay
1–2 × 22 kW or 30 kW DC fast chargers on a dedicated circuit, with UPS or genset backup for essential operations.
Doctor On-Call Parking
2–4 × 11 kW chargers with reservation via staff app. Guarantees charged vehicle when called in urgently.
Safety-first install for healthcare environments
We design hospital EV charging installations with isolation between EV circuits and critical medical equipment circuits, Type A/B RCCB protection per IEC 61851-1, low-harmonic front ends to avoid interference, surge protection, and UPS/genset integration for priority ambulance use cases. Every Tech OVN install includes an SLD review signed off by a certified electrical engineer before commissioning.
For the charging metering side — critical for revenue-sharing with a CPO partner or for internal cost allocation between staff and visitor usage — pair the chargers with Titan EV charging metering on the upstream AC circuit.
Frequently asked questions
Six questions hospital facility directors ask before approving an EV charging installation.
Related pages
Type 2 EV Charger
22 kW AC charger with OCPP support — standard for hospital visitor and staff parking.
Learn More →EV Charging Metering Solution
Revenue-grade sub-metering — required for CPO revenue sharing and staff payroll billing.
Learn More →EV Charger Sizing Calculator
Plan the right mix of AC and DC fast chargers for your facility.
Learn More →Plan a safe, reliable hospital EV rollout
Share your site layout, critical-load diagram, and target use cases. We return a compliance-ready BOQ within 48 hours.